Hipot Safety Analyser

Hipot safety analyser S 1801M
  • Plug-in 14" / 3 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 10 - 30 A / 0 - 400 mΩ
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz
Hipot safety analyser LG 1800B
  • Ergonomic desktop device
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ 
  • Ground bond test AC: 10 - 30 A / 0 - 400 mΩ 
  • Equivalent leakage current test AC: 100 - 270 V / 0 - 10 mA 
  • Continuity test DC: 24 V / 0 - 600 mA
  • Function test / current consumption AC: 4 A (option: 1 A, 10 A or 16 A) 
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz
Hipot safety analyser KT 1880B
  • Plug-in 19'' / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 10 - 30 A / 0 - 400 mΩ
  • Equivalent leakage current test AC: 100 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Function test / current consumption AC: 4 A (option: 1 A, 10 A or 16 A)
  • Wide-range power supply unit: 90 to 253 V / 50 Hz / 60 Hz
Hipot safety analyser LG 1805B
  • Ergonomic desktop device
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω
  • ARC detection (optional): 0 - 100 %
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Short-circuit test DC: 24 V / > 600 mA
  • Resistance measurement (optional): 1 - 1.000 Ω
  • Function test AC / DC: 0 - 300 V / 0 - 16 A
  • Active power measurement (optional): 0 - 4.000 W
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz
Hipot safety analyser KT 1886B
  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω 
  • ARC detection (optional): 0 - 100 %
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Short-circuit test DC: 24 V / > 600 mA
  • Resistance measurement (optional): 0 - 1,000 Ω
  • Function test AC/DC: 0 - 300 V / 0 - 16 A
  • Active power measurement (optional): 0 - 4,000 W
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz
Hipot safety analyser KT 1886J
  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 100 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 50 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω 
  • ARC detection (optional): 0 - 100 %
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Short-circuit test DC: 24 V / > 600 mA
  • Resistance measurement (optional): 0 - 1.000 Ω
  • Function test AC/DC: 0 - 300 V / 0 - 16 A
  • Active power measurement (optional): 0 - 4,000 W
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz
Hipot safety analyser KT 1885K
  • Plug-in 19'' / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Short-circuit test DC: 24 V / > 600 mA
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz
  • Only for 19" system installation
Hipot safety analyser KT 1885L
  • Plug-in 19'' / 5 HU 
  • High voltage test AC: 100 - 5,500 V / 0 - 100 mA 
  • High voltage test DC: 100 - 6,000 V / 0 - 100 mA 
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ 
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω 
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA 
  • Continuity test DC: 24 V / 0 - 600 mA 
  • Short-circuit test DC: 24 V / > 600 mA 
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz 
  • Only for 19" system installation